Our DTM-ILCA strain gauge load cell amplifier provides signal conditioning for strain gauges and load cells, for just $175 US.

| 5 volt DC, 20 mAmp Power Input | |||||||||||||||||
| 0-4.5 volt output | |||||||||||||||||
| Designed for typical bridge resistance of approximately 350 ohms | |||||||||||||||||
8 pin Female Molex Mini Fit Jr (tm) connector:
| |||||||||||||||||
| 2.5 x 2.5 x 1 inches | |||||||||||||||||
| Zero and Span 15 turn precision pots | |||||||||||||||||
| 65 gms | |||||||||||||||||
| Environmental: 40 to 140 deg F for enclosure, 0 to 80% humidity |
8 pin Molex connector with pigtail and terminals sold separately.